Indicate a (sys)upgrade via leds as well. It brings the lantiq diag.sh
script en par with the other implementations using devicetree aliases
to define multiple leds for boot status indication.
By default, use the boot finished led to indicate an upgrade for now.
Signed-off-by: Mathias Kresin <dev@kresin.me>
Updated the devicetree source files to make use of the following
upstreamed drivers:
- xrx200 ethernet phy
- reset controller unit
- dwc2
- fpi
Use our custom xrx200 ethernet phy compatible to support boards, which
have switched the vr9 revision during lifetime, with a single devicetree
source file.
By switching to the dwc2 driver + usb phy framework, we don't need to used
our custom gpio power patch and can use a fixed regulator instead.
Signed-off-by: Hauke Mehrtens <hauke@hauke-m.de>
Signed-off-by: Mathias Kresin <dev@kresin.me>
This just copies the patches, configuration and dts files into the
directories hich are used for kernel 4.14.
Signed-off-by: Hauke Mehrtens <hauke@hauke-m.de>
Move the devicetree source files to a kernel specific directory in
preparation of adding kernel 4.14 support.
Rename the subtarget kernel config files to match a specific kernel
version.
Signed-off-by: Mathias Kresin <dev@kresin.me>
Rename the gphy firmware to match the name requested by kernel 4.14 and
update the devicetree source files to use the new name.
Update the u-boot lantiq Makefile to be compatible with the new names as
well.
Signed-off-by: Mathias Kresin <dev@kresin.me>
This was broken in 7bab49fd ("lantiq: add compatible strings to dts
files"), causing for the dm200 garbled serial output during boot, and
likely other issues.
Signed-off-by: Thomas Nixon <tom@tomn.co.uk>
[fix the compat string of the P2601HNFX as well]
Signed-off-by: Mathias Kresin <dev@kresin.me>
Netgear DM200 is an inexpensive VDSL modem:
CPU: VRX220 MIPS 34Kc 5.6 @ 500Mhz
RAM: 64MiB
Flash: 8MiB
Ethernet: 1x100M
DSL: VDSL2+, ADSL2+
reset button, 3x bi-color LEDs
Serial port is 115200 baud, on the 4 pin header; pins from the bottom to
top are GND, RX, TX.
To upgrade from the vendor firmware, upload factory.img
The DM200 bootloader supports flashing over TFTP; hold the reset button
while powering on the device, and wait for the power light to start
flashing green before releasing. The device is now listening on
192.168.0.1/24, and can be sent a factory.img or a netgear image with a
TFTP put.
Once the image is loaded, it will be written to the flash, and the
device will reboot; this will take a few minutes.
Thanks to Edward O'Callaghan and Baptiste Jonglez, who implemented their
own ports for this device and provided valuable feedback.
Signed-off-by: Thomas Nixon <tom@tomn.co.uk>