lantiq: fix dts compatible string

This was broken in 7bab49fd ("lantiq: add compatible strings to dts
files"), causing for the dm200 garbled serial output during boot, and
likely other issues.

Signed-off-by: Thomas Nixon <tom@tomn.co.uk>
[fix the compat string of the P2601HNFX as well]
Signed-off-by: Mathias Kresin <dev@kresin.me>
master
Thomas Nixon 7 years ago committed by Mathias Kresin
parent 0f72690a2d
commit 9fc9fbeb97
  1. 2
      target/linux/lantiq/dts/DM200.dts
  2. 2
      target/linux/lantiq/dts/P2601HNFX.dts

@ -5,7 +5,7 @@
#include <dt-bindings/input/input.h>
/ {
compatible = "netgear,dm200", "lantiq,xway", "lantiq,ar9";
compatible = "netgear,dm200", "lantiq,xway", "lantiq,vr9";
model = "Netgear DM200";
chosen {

@ -5,7 +5,7 @@
#include <dt-bindings/input/input.h>
/ {
compatible = "zyxel,p-2601hn", "lantiq,xway", "lantiq,danube";
compatible = "zyxel,p-2601hn", "lantiq,xway", "lantiq,ar9";
model = "ZyXEL P-2601HN-Fx";
chosen {