## Minio Azure Gateway Limitations
|
||
|
|
||
|
Gateway inherits the following Azure limitations:
|
||
|
|
||
|
- Maximum Multipart part size is 100MB.
|
||
|
- Maximum Multipart object size is 10000*100 MB = 1TB
|
||
|
- No support for prefix based bucket policies. Only top level bucket policy is supported.
|
||
|
- Gateway restart implies all the ongoing multipart uploads must be restarted.
|
||
|
i.e clients must again start with NewMultipartUpload
|
||
|
This is because S3 clients send metadata in NewMultipartUpload but Azure expects metadata to
|
||
|
be set during CompleteMultipartUpload (PutBlockList in Azure terminology). We store the metadata
|
||
|
sent by the client during NewMultipartUpload in memory so that it can be set on Azure later during
|
||
|
CompleteMultipartUpload. When the gateway is restarted this information is lost.
|
||
|
- Bucket names with "." in the bucket name is not supported.
|
||
|
- Non-empty buckets get removed on a DeleteBucket() call.
|
||
|
|
||
|
Other limitations:
|
||
|
- Current implementation of ListMultipartUploads is incomplete. Right now it returns if the object with name "prefix" has any uploaded parts.
|
||
|
- Bucket notification not supported.
|