You can not select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
 
 
 
 
 
 
freifunkist-firmware/package/network/utils/iw/patches/001-nl80211_h_sync.patch

100 lines
4.8 KiB

--- a/nl80211.h
+++ b/nl80211.h
@@ -1761,6 +1761,9 @@ enum nl80211_commands {
* @NL80211_ATTR_REG_INDOOR: flag attribute, if set indicates that the device
* is operating in an indoor environment.
*
+ * @NL80211_ATTR_WIPHY_ANTENNA_GAIN: Configured antenna gain. Used to reduce
+ * transmit power to stay within regulatory limits. u32, dBi.
+ *
* @NUM_NL80211_ATTR: total number of nl80211_attrs available
* @NL80211_ATTR_MAX: highest attribute number currently defined
* @__NL80211_ATTR_AFTER_LAST: internal use
@@ -2130,6 +2133,8 @@ enum nl80211_attrs {
NL80211_ATTR_REG_INDOOR,
+ NL80211_ATTR_WIPHY_ANTENNA_GAIN,
+
/* add attributes here, update the policy in nl80211.c */
__NL80211_ATTR_AFTER_LAST,
@@ -2620,16 +2625,17 @@ enum nl80211_band_attr {
* an indoor surroundings, i.e., it is connected to AC power (and not
* through portable DC inverters) or is under the control of a master
* that is acting as an AP and is connected to AC power.
- * @NL80211_FREQUENCY_ATTR_GO_CONCURRENT: GO operation is allowed on this
+ * @NL80211_FREQUENCY_ATTR_IR_CONCURRENT: IR operation is allowed on this
* channel if it's connected concurrently to a BSS on the same channel on
* the 2 GHz band or to a channel in the same UNII band (on the 5 GHz
- * band), and IEEE80211_CHAN_RADAR is not set. Instantiating a GO on a
- * channel that has the GO_CONCURRENT attribute set can be done when there
- * is a clear assessment that the device is operating under the guidance of
- * an authorized master, i.e., setting up a GO while the device is also
- * connected to an AP with DFS and radar detection on the UNII band (it is
- * up to user-space, i.e., wpa_supplicant to perform the required
- * verifications)
+ * band), and IEEE80211_CHAN_RADAR is not set. Instantiating a GO or TDLS
+ * off-channel on a channel that has the IR_CONCURRENT attribute set can be
+ * done when there is a clear assessment that the device is operating under
+ * the guidance of an authorized master, i.e., setting up a GO or TDLS
+ * off-channel while the device is also connected to an AP with DFS and
+ * radar detection on the UNII band (it is up to user-space, i.e.,
+ * wpa_supplicant to perform the required verifications). Using this
+ * attribute for IR is disallowed for master interfaces (IBSS, AP).
* @NL80211_FREQUENCY_ATTR_NO_20MHZ: 20 MHz operation is not allowed
* on this channel in current regulatory domain.
* @NL80211_FREQUENCY_ATTR_NO_10MHZ: 10 MHz operation is not allowed
@@ -2641,7 +2647,7 @@ enum nl80211_band_attr {
* See https://apps.fcc.gov/eas/comments/GetPublishedDocument.html?id=327&tn=528122
* for more information on the FCC description of the relaxations allowed
* by NL80211_FREQUENCY_ATTR_INDOOR_ONLY and
- * NL80211_FREQUENCY_ATTR_GO_CONCURRENT.
+ * NL80211_FREQUENCY_ATTR_IR_CONCURRENT.
*/
enum nl80211_frequency_attr {
__NL80211_FREQUENCY_ATTR_INVALID,
@@ -2659,7 +2665,7 @@ enum nl80211_frequency_attr {
NL80211_FREQUENCY_ATTR_NO_160MHZ,
NL80211_FREQUENCY_ATTR_DFS_CAC_TIME,
NL80211_FREQUENCY_ATTR_INDOOR_ONLY,
- NL80211_FREQUENCY_ATTR_GO_CONCURRENT,
+ NL80211_FREQUENCY_ATTR_IR_CONCURRENT,
NL80211_FREQUENCY_ATTR_NO_20MHZ,
NL80211_FREQUENCY_ATTR_NO_10MHZ,
@@ -2672,6 +2678,8 @@ enum nl80211_frequency_attr {
#define NL80211_FREQUENCY_ATTR_PASSIVE_SCAN NL80211_FREQUENCY_ATTR_NO_IR
#define NL80211_FREQUENCY_ATTR_NO_IBSS NL80211_FREQUENCY_ATTR_NO_IR
#define NL80211_FREQUENCY_ATTR_NO_IR NL80211_FREQUENCY_ATTR_NO_IR
+#define NL80211_FREQUENCY_ATTR_GO_CONCURRENT \
+ NL80211_FREQUENCY_ATTR_IR_CONCURRENT
/**
* enum nl80211_bitrate_attr - bitrate attributes
@@ -2830,7 +2838,7 @@ enum nl80211_sched_scan_match_attr {
* @NL80211_RRF_AUTO_BW: maximum available bandwidth should be calculated
* base on contiguous rules and wider channels will be allowed to cross
* multiple contiguous/overlapping frequency ranges.
- * @NL80211_RRF_GO_CONCURRENT: See &NL80211_FREQUENCY_ATTR_GO_CONCURRENT
+ * @NL80211_RRF_IR_CONCURRENT: See &NL80211_FREQUENCY_ATTR_IR_CONCURRENT
* @NL80211_RRF_NO_HT40MINUS: channels can't be used in HT40- operation
* @NL80211_RRF_NO_HT40PLUS: channels can't be used in HT40+ operation
* @NL80211_RRF_NO_80MHZ: 80MHz operation not allowed
@@ -2847,7 +2855,7 @@ enum nl80211_reg_rule_flags {
NL80211_RRF_NO_IR = 1<<7,
__NL80211_RRF_NO_IBSS = 1<<8,
NL80211_RRF_AUTO_BW = 1<<11,
- NL80211_RRF_GO_CONCURRENT = 1<<12,
+ NL80211_RRF_IR_CONCURRENT = 1<<12,
NL80211_RRF_NO_HT40MINUS = 1<<13,
NL80211_RRF_NO_HT40PLUS = 1<<14,
NL80211_RRF_NO_80MHZ = 1<<15,
@@ -2859,6 +2867,7 @@ enum nl80211_reg_rule_flags {
#define NL80211_RRF_NO_IR NL80211_RRF_NO_IR
#define NL80211_RRF_NO_HT40 (NL80211_RRF_NO_HT40MINUS |\
NL80211_RRF_NO_HT40PLUS)
+#define NL80211_RRF_GO_CONCURRENT NL80211_RRF_IR_CONCURRENT
/* For backport compatibility with older userspace */
#define NL80211_RRF_NO_IR_ALL (NL80211_RRF_NO_IR | __NL80211_RRF_NO_IBSS)