You can not select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
 
 
 
 
 
 
freifunkist-firmware/package/kernel/mac80211/patches/314-mac80211-Requeue-work-a...

103 lines
3.4 KiB

From: Sachin Kulkarni <Sachin.Kulkarni@imgtec.com>
Date: Tue, 12 Jan 2016 14:30:19 +0530
Subject: [PATCH] mac80211: Requeue work after scan complete for all VIF
types.
During a sw scan ieee80211_iface_work ignores work items for all vifs.
However after the scan complete work is requeued only for STA, ADHOC
and MESH iftypes.
This occasionally results in event processing getting delayed/not
processed for iftype AP when it coexists with a STA. This can result
in data halt and eventually disconnection on the AP interface.
Signed-off-by: Sachin Kulkarni <Sachin.Kulkarni@imgtec.com>
Cc: linux-wireless@vger.kernel.org
Cc: johannes@sipsolutions.net
---
--- a/net/mac80211/ibss.c
+++ b/net/mac80211/ibss.c
@@ -1731,7 +1731,6 @@ void ieee80211_ibss_notify_scan_complete
if (sdata->vif.type != NL80211_IFTYPE_ADHOC)
continue;
sdata->u.ibss.last_scan_completed = jiffies;
- ieee80211_queue_work(&local->hw, &sdata->work);
}
mutex_unlock(&local->iflist_mtx);
}
--- a/net/mac80211/mesh.c
+++ b/net/mac80211/mesh.c
@@ -1369,17 +1369,6 @@ out:
sdata_unlock(sdata);
}
-void ieee80211_mesh_notify_scan_completed(struct ieee80211_local *local)
-{
- struct ieee80211_sub_if_data *sdata;
-
- rcu_read_lock();
- list_for_each_entry_rcu(sdata, &local->interfaces, list)
- if (ieee80211_vif_is_mesh(&sdata->vif) &&
- ieee80211_sdata_running(sdata))
- ieee80211_queue_work(&local->hw, &sdata->work);
- rcu_read_unlock();
-}
void ieee80211_mesh_init_sdata(struct ieee80211_sub_if_data *sdata)
{
--- a/net/mac80211/mesh.h
+++ b/net/mac80211/mesh.h
@@ -362,14 +362,10 @@ static inline bool mesh_path_sel_is_hwmp
return sdata->u.mesh.mesh_pp_id == IEEE80211_PATH_PROTOCOL_HWMP;
}
-void ieee80211_mesh_notify_scan_completed(struct ieee80211_local *local);
-
void mesh_path_flush_by_iface(struct ieee80211_sub_if_data *sdata);
void mesh_sync_adjust_tbtt(struct ieee80211_sub_if_data *sdata);
void ieee80211s_stop(void);
#else
-static inline void
-ieee80211_mesh_notify_scan_completed(struct ieee80211_local *local) {}
static inline bool mesh_path_sel_is_hwmp(struct ieee80211_sub_if_data *sdata)
{ return false; }
static inline void mesh_path_flush_by_iface(struct ieee80211_sub_if_data *sdata)
--- a/net/mac80211/mlme.c
+++ b/net/mac80211/mlme.c
@@ -3978,8 +3978,6 @@ static void ieee80211_restart_sta_timer(
if (!ieee80211_hw_check(&sdata->local->hw, CONNECTION_MONITOR))
ieee80211_queue_work(&sdata->local->hw,
&sdata->u.mgd.monitor_work);
- /* and do all the other regular work too */
- ieee80211_queue_work(&sdata->local->hw, &sdata->work);
}
}
--- a/net/mac80211/scan.c
+++ b/net/mac80211/scan.c
@@ -314,6 +314,7 @@ static void __ieee80211_scan_completed(s
bool was_scanning = local->scanning;
struct cfg80211_scan_request *scan_req;
struct ieee80211_sub_if_data *scan_sdata;
+ struct ieee80211_sub_if_data *sdata;
lockdep_assert_held(&local->mtx);
@@ -373,7 +374,15 @@ static void __ieee80211_scan_completed(s
ieee80211_mlme_notify_scan_completed(local);
ieee80211_ibss_notify_scan_completed(local);
- ieee80211_mesh_notify_scan_completed(local);
+
+ /* Requeue all the work that might have been ignored while
+ * the scan was in progress
+ */
+ list_for_each_entry_rcu(sdata, &local->interfaces, list) {
+ if (ieee80211_sdata_running(sdata))
+ ieee80211_queue_work(&sdata->local->hw, &sdata->work);
+ }
+
if (was_scanning)
ieee80211_start_next_roc(local);
}