From: Vittorio Gambaletta <openwrt@vittgam.net>
|
||
|
Date: Fri, 01 Jan 2016 00:00:01 +0100
|
||
|
Subject: [PATCH 2/3] net: mediatek: Fix comment in rt3050 ethernet switch driver.
|
||
|
|
||
|
Line 444 is actually enabling all switch ports by setting the disable bits
|
||
|
to 0. This needs to be done because the bootloader sets all ports to disabled
|
||
|
by default (which is the case for at least one router based on RT5350).
|
||
|
|
||
|
So, this patch fixes the comment in line 443.
|
||
|
|
||
|
Signed-off-by: Vittorio Gambaletta <openwrt@vittgam.net>
|
||
|
---
|
||
|
|
||
|
--- a/drivers/net/ethernet/mediatek/esw_rt3050.c
|
||
|
+++ b/drivers/net/ethernet/mediatek/esw_rt3050.c
|
||
|
@@ -440,7 +440,7 @@ static void esw_hw_init(struct rt305x_es
|
||
|
(RT305X_ESW_PORTS_ALL << RT305X_ESW_PFC1_EN_VLAN_S),
|
||
|
RT305X_ESW_REG_PFC1);
|
||
|
|
||
|
- /* Enable Back Pressure, and Flow Control */
|
||
|
+ /* Enable all ports, Back Pressure and Flow Control */
|
||
|
esw_w32(esw, ((RT305X_ESW_PORTS_ALL << RT305X_ESW_POC0_EN_BP_S) |
|
||
|
(RT305X_ESW_PORTS_ALL << RT305X_ESW_POC0_EN_FC_S)),
|
||
|
RT305X_ESW_REG_POC0);
|